Call Us at 1-800-766-0884
|
|

|
Pain Generator Detection

Sensitivity and Specificity in Detecting Pre-DRG Pathology
Evidence Based Medicine
The patented modulated Neural-Scan signal is designed to isolate specific types of sensory fibers. This is especially valuable in helping detect dysfunction in the A-delta fibers for evaluation of possible pre-DRG pathway pathology. Verification of firing is supported by the well documented fact that A-delta fibers are literally "hardwired" to the ventral motor pathway, so when they fire they not only produce a detectable action potential but additonally cause a subthreshold potential in the associated ventral motor pathway. Neural-Scan alone, or in conjunction with the potentiometer, can in a few minutes assess all the major nerve in a region to help detect the one or two requiring the highest voltage amplitude to initiate firing. Most important, the patient is his own control independent of age, gender or population data. As documented in medical text, conventional EMG/NCV cannot access the pain generating fibers of the pre-DRG in the absence of gross motor deficit, which is fairly rare, since most neck and back pain patient do not complain of, or demonstrate, weakness.
The Fallacy of Spontaneous Recovery
Based on the studies by Donelson et al. The Low Back Pain Experience: Natural History Survey - North American McKenzie Conf. Orando FL (2000) and Wayman et al. A Prospective Follow-Up Study of Low Back Pain in the Community - Spine 2000 that Though 40 - 50% of low back pain cases spontaneously recover within two weeks and 80 - 90% have recovered by two months, 60 - 90% suffer recurrences with progressively worsening, increased disability, longer duration and increasing peripheral radiation.
It would seem logical that the key is accurate diagnosis of the level and side of nerve root lesion so appropriate intervention can prevent recurrences and increasing disability. The Neural-Scan can be a valuable tool in this regard.
Fibromyalgia
The Neural-Scan has been shown to detect pre-DRG pathology in most of these patients and has been reported to allow successful treatment in many such cases.
Double Objective Proof
Preliminary findings support that pre-DRG pathology may have a close correlation with abnormal vertebral motion as viewed on A-P lateral bending x-ray. It is suspected that diminished proprioceptive sensory input can affect spinal motor function, which is well documented in Guyton & Hall, and other medical physiology textbooks, that the small intrinsic muscles of the spine are under major controlled on a level by level in the spinal cord. See Guyton & Hall 9th Edition Page 705
Step by Step - Understanding Neural-Scan's Importance
|
|

|
SPECIFICATIONS
 - Control: Custom ASIS Digital Logic Controller
- Size: 12.5 wide, 11.5" deep, and 5" high
- Weight: 10.5 lb.
- LCD Display: 1" X 2"
- Power: 8 disposable alkaline batteries
- Battery Life: 12 months under normal use
- Output: 5 Hz, 250 Hz and 2000 Hz waveform*
- Output Current: 0 to 9.99 mA
- Resolution Measurement: Non-Stepped Gradient
- Device Features: Audible Function Changes, Power Test Modality, Automatic Calibration, Auto Low Power Warning With Flashing Red Light, Auto Power-up at 250 Hz frequency
- Two Electrodes: One single large common ground (sponge type). The second electrode is a saline dipped Q-Tip in a hand held gold tip probe*
- Potentiometer: Conductive plastic with only 1% dynamic noise.
- European Clearances: The Neual-Scan is a Class I device and carries the CE mark.
- The NEUAL-SCAN was registered and cleared for marketing by the FDA as safe and effective December 1, 1997 additional clearances were granted May 1998 and changes were made by FDA file letter.
|
|

|
|
|

|
|


|
|
Sole Distributor and Manufacturer: NDA, Inc. - Neural-ScanTM NCSs SystemTM
PHONE: 1-800-766-0884 - E-MAIL: email@nervepathology.com
Home | Learn More | Studies | News | Contact Us | Purchase
This website is not for general public use. It is meant for physician reference only. Nothing presented is meant to represent or imply use other than the FDA Indication and usage.
FDA Indications and Usage: The Neural-ScanTM NCSs is a diagnostic device that allows the quantitative detection of various sensory neurological impairments caused by various pathological conditions or toxic substance exposures. The subject population for whom this device can be used for diagnostic purposes includes any individual capable of communicating the perception of cutaneous sensation (with the potentiometer, which has a separate FDA clearance, the test is not dependent on the subject reporting perception of the cutaneous sensation, since the action potential of the nerve firing is detectable by the potentiometer). The Neural-ScanTM NCSs diagnostic examination may be conducted as part the neurological examination or for screening to detect peripheral neuropathies.
Legal Notice
DOCUMENTS
Neuro-Diagnostic Associates (NDA), Incorporated. gives permission to use documents on this web site provided that:
- The NDA, Inc. copyright appears in copies and a permission notice appear, © 2007 NDA, Inc.
- Documents from this site are for informational and non-commercial or personal use only. Such will not be copied or posted to any network computer or broadcast or published in any media or method now or hereafter developed, and
- No modification of any document is made and no unauthorized purpose is prohibited by law. Violation may result in civil and/or criminal penalties.
Materials do not use the design or layout of the website.
INFORMATION ON NDA, INCORPORATED'S WEBSITE INCLUDING SPECIFICATIONS, APPEARANCE AND APPLICABILITY MAY BE SUBJECT TO CHANGE WITHOUT NOTICE. NO REPRESENTATIONS IS MADE OR IMPLIED AS TO THE SUITABILITY OF THE INFORMATION ON THIS SITE FOR ANY PURPOSE. THE FULL CONTENTS ARE PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND AND ARE SUBJECT TO CHANGE WITHOUT NOTICE. ANY TYPE OF RISK WHICH MAY ARISE OUT OF USE OF THIS INFORMATION REMAINS WITH THE RECIPIENT. IN NO EVENT SHALL NDA, INCORPORATED BE LIABLE FOR ANY DIRECT, CONSEQUENTIAL, INCIDENTAL, SPECIAL, PUNITIVE OR OTHER DAMAGES (INCLUDING WITHOUT LIMITATION, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION), EVEN IF NDA, INCORPORATED HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
TRADEMARK NOTICE
All trademarks displayed on this website are subject to the U.S. trademark law, which support that any unauthorized use of trademarks is strictly prohibited.
Copyright © 2007 Neural-ScanTM NCSs SystemTM All Rights Reserved.
|
|